Products
ApplicationsStoreResourcesSupportAbout
MinION/GridION Flow Cell (DNA)
FLO-MIN114

These flow cells are designed for MinION and GridION devices. They feature our R10 nanopore which pairs with Kit 14 chemistry to deliver rich genomic and epigenomic data at our highest accuracy.

Product lead time: 1 week

3Released
  • Products from Oxford Nanopore Technologies that have completed their Early Access
  • Users can continue to provide feedback through feature request pinboard
  • Warranty periods extended to 1 – 3 months
  • Product continues to iterate with upgrade notifications of up to 3 months
  • Lead time visible in store
  • Product subject to availability

Information

A MinION/GridION Flow Cell (DNA) is a consumable used with MinION and GridION devices. It contains the proprietary sensor array, Application-Specific Integrated Circuit (ASIC), and R10 nanopores. The R10 series of nanopores contains a double reader-head, and is suitable for experiments where high consensus accuracy is required. Paired with the Kit 14 chemistry, the flow cell generates data at a modal accuracy above 99%.

This flow cell supports all our V14 kits, including the Ligation Sequencing Kit V14, Rapid Sequencing Kit V14 and barcoding. A full compatibilities list is available below.

Note: All flow cells will be shipped with flow cell light shields.

How it works:

A user simply adds their prepared library to the flow cell, installs the flow cell light shield and starts their sequencing experiment.

Data is accumulated over time as DNA is sequenced by the nanopores. Individual read files are generated and are immediately available for analysis.

As data is streamed in real-time, a user can choose to stop a run as soon as sufficient data is gathered. A flow cell contains sufficient buffer to run for ~72 hours (under optimal conditions) and a user can choose to run continuously or run, stop, wash, and load a new sample until the buffer and nanopores are exhausted.

Shipping and logistics:

MinION/GridION Flow Cells are packed individually with a light shield; however, bulk order options are available.

For flow cells ordered directly from Oxford Nanopore only: you may schedule your flow cell order into separate deliveries at checkout. All flow cells must be delivered within 9 months of the order date. If purchasing the MinION Mk1D Starter pack, the flow cell order cannot be scheduled into separate deliveries and will arrive in a single shipment.

Flow cells are sensitive to temperature. To ensure optimal results during use, consumables are shipped with cool packs. It is not unusual for the cool packs to be warm when you receive them. For optimal results, immediately store your new flow cells at their correct temperatures.

We recommend that flow cells should be stored between 2°C and 8°C until use. Flow cells should not be frozen at any point, or come into contact with frozen elements, such as the back panel of a refrigerator or frozen cool packs.

The delivery charges are calculated when a quote is raised or during checkout. Once an order is made, the delivery ID and delivery information can be tracked in the Store.

Storage and stability:

Flow cells should be stored unopened between 2°C and 8°C until ready to use.

We recommend you check your flow cell before preparing your DNA/RNA library as part of the warranty process.

Flow cell returns:

The flow cell pouch provided serves as the flow cells returns packaging. Flow cells contain finite materials which, when returned to Oxford Nanopore, are responsibly recycled.

More information on how to carry out a return can be found on the Nanopore Community.

Workflow

MinION/GridION Flow Cells are provided in a sealed pouch.

Flow cells should be stored unopened between 2°C and 8°C until ready to use.

Prior to use, the flow cell can be checked by performing a flow cell check using MinKNOW (the MinION and GridION device software). The flow cell check will report the number of nanopores available for sequencing.

Once the flow cell check has been performed satisfactorily, the flow cell is ready to be used for experiments. The exact protocol and reagent kits used will depend on the experiment being run.

Please return your flow cells and light shields to Oxford Nanopore Technologies after use.

Safety and legal

Safety Data Sheet for MinION/GridION Flow Cell DNA (FLO-MIN114)

The warranty period for this product is 12 weeks from receipt by the customer.

Customers are required to perform a flow cell check before use, within 12 weeks of receipt. Oxford Nanopore Technologies will replace any unused flow cell with fewer than 800 nanopores, when the result is reported within two days of performing the flow cell check, and when the storage recommendations have been followed.

There is a 9-month contract length available for all consumable purchases. For more information, please see the Nanopore Product Terms and Conditions.

What's in the box

MinION/GridION Flow Cells are shipped in a sealed pouch with a light shield.

Flow cell packaging

This packaging also serves as the flow cell returns kit. Users are requested to return their flow cells after use so that they can be responsibly recycled by Oxford Nanopore Technologies.

Compatibility

Kits

  • Ligation Sequencing Kit V14 (SQK-LSK114)
  • Ligation Sequencing Kit XL V14 (SQK-LSK114-XL)
  • Rapid Sequencing Kit V14 (SQK-RAD114)
  • Rapid Barcoding Kit 24 V14 (SQK-RBK114.24)
  • Rapid Barcoding Kit 96 V14 (SQK-RBK114.96)
  • Native Barcoding Kit 24 V14 (SQK-NBD114.24)
  • Native Barcoding Kit 96 V14 (SQK-NBD114.96)
  • Ultra-Long Sequencing Kit V14 (SQK-ULK114)
  • PCR Expansion (EXP-PCA001)
  • PCR Barcoding Expansion 1-12 (EXP-PBC001)
  • PCR Barcoding Expansion 1-96 (EXP-PBC096)
  • Rapid PCR Barcoding Kit 24 V14 (SQK-RPB114.24)
  • cDNA-PCR Sequencing Kit V14 (SQK-PCS114)
  • cDNA-PCR Barcoding Kit V14 (SQK-PCB114.24)
  • 16S Barcoding Kit 24 V14 (SQK-16S114.24)